Products
Digital Load Cells
Applications
Transcell’s multi-column digital load cells deliver precise load measurements up to 50 tons. The load cell features a RS485 transmission interface with two-wire communication. The design operates between -10℃ and +40℃. Our rugged digital load cells support force measuring applications in multiple industries, including:
- Truck scales
- Aeronautics
- Storage tanks
- Industrial loading
- Mobile industrial equipment
Need a Custom Solution?
Contact UsFeatures & Benefits
- Multi-column Load Cell
- Total Stainless Steel Construction
- Hermetically Sealed
- Easy to Install
- High Accuracy
- High Stability
- Safe Overload 150%
Technical Specifications
View All Model Details
CD-LD V17.7
CD V18.5
CD-SD V19.6
CD-SD2 V19.8
DBSQD V18.5
DBSQD2 V18.4
CD-LD V17.7
Specifications | |
---|---|
Zero Balance | ±1.5% of rated output |
Class of Accuracy | C3?C6 |
Data Transmission | RS485 interface with 2 wires Dual communication |
Hysteresis | Transcell definition |
Data Refresh Frequency | 80HZ/S |
Rate of Data Signalling | 57600BPS |
Operating Temperature Range | -10°C - +40°C |
Load cell number range | 1-10 |
Safe Overload | 150% |
Insulation Resistance | ≥2000 M ohm (50V DC) |
Rated Excitation | 9-12V |
Protection Grade | IP68 |
CD V18.5
Specifications | |
---|---|
Rated Output | 2.0mV/V ± 10% |
Zero Balance | ± 1% of rated output |
Creep | ± 0.03% of applied load |
Nonlinearity | ± 0.03% of rated output |
Hysteresis | ± 0.03% of rated output |
Repeatability | ± 0.03% of rated output |
Temp Effect on Output | ± 0.002% of reading/°C |
Temp Effect on Zero | ± 0.002% of output/°C |
Cable Length | 6m [20.28ft] |
Safe Temp Range | -10 to +70°C |
Temp Comp Range | -10 to +40°C |
Safe Overload | 150% of capacity |
Input Impedance | 410 Ω |
Output Impedance | 350 Ω |
Insulation Resistance | 5000 MΩ |
Rated Excitation | 10 V DC/AC |
Max Excitation | 15 V DC/AC |
CD-SD V19.6
Specifications | |
---|---|
Zero Balance | ±1.5% of rated output |
Class of Accuracy | C3 / C6 |
Data Transmission | RS485 interface with 2 wires Dual communication |
Communication Protocol | Transcell definition |
Data Refresh Frequency | 80 Hz/s |
Rate of Data Signaling | 57600 bps |
Load Cell Number Range | 1-10 |
Safe Temp Range | -10 to +70℃ |
Temp Comp Range | -10 to +40℃ |
Safe Overload | 150% of capacity |
Insulation Resistance | 2000 MΩ |
Rated Excitation | 9-12 V DC/AC |
CD-SD2 V19.8
Specifications | |
---|---|
Zero Balance | ±1.5% of rated output |
Data Transmission | RS485 interface with 2 wires Dual communication |
Communication Protocol | Transcell definition |
Data Refresh Frequency | 80 Hz/s |
Rate of Data Signaling | 57600 bps |
Load Cell Number Range | 1-10 |
Safe Temp Range | -10 to +70℃ |
Temp Comp Range | -10 to +40℃ |
Safe Overload | 150% of capacity |
Insulation Resistance | 2000 MΩ |
Rated Excitation | 9-12 V DC/AC |
DBSQD V18.5
Specifications | |
---|---|
Rated Output | 300000 counts |
Creep | ± 0.02% of applied load |
Nonlinearity | ± 0.03% of rated output |
Hysteresis | ± 0.03% of rated output |
Repeatability | ± 0.03% of rated output |
Temp Effect on Output | ± 0.002% of reading/°C |
Temp Effect on Zero | ± 0.002% of output/°C |
Cable Length | 13m [42.65ft] / 15m [49.21ft] |
Max Output Distance | 1000 m |
Safe Temp Range | -10 to +70°C |
Temp Comp Range | -10 to +40°C |
Safe Overload | 150% of capacity |
Rated Excitation | 8 V DC |
Max Excitation | 8 V DC |
Input Current | 40 mA |
Baud Rate | 19200 bps |
DBSQD2 V18.4
Specifications | |
---|---|
Rated Output | 60000 counts |
Creep | ± 0.02% of applied load |
Nonlinearity | ± 0.03% of rated output |
Hysteresis | ± 0.03% of rated output |
Repeatability | ± 0.03% of rated output |
Temp Effect on Output | ± 0.002% of reading/°C |
Temp Effect on Zero | ± 0.002% of output/°C |
Cable Length | 4m [13.12ft] / 7m [22.97ft] / 15m [49.21ft] / 30m [98.43ft] |
Safe Temp Range | -10 to +70°C |
Temp Comp Range | -10 to +40°C |
Safe Overload | 150% of capacity |
Rated Excitation | 6-12 V DC |
Max Output Distance | 100 m |
Input Current | Max 40 mA |
Baud Rate | 57600 bps |
CD-LD-V17.7 | View Sheet |
CD V18.5 | View Sheet |
CD-SD_Datasheet_Eng._V19.6 | View Sheet |
CD-SD2_Datasheet_Eng._V19.8 | View Sheet |
DBSQD V18.5 | View Sheet |
DBSQD2_Datasheet_Eng_V18.4 | View Sheet |
IndustriesIndustries
Experience to Solve Your Challenges